Specifications

Manufacturer   ВЕНТС

Description VENTS VUT H

Sound- and heat-insulated air handling units with an air flow capacity up to 2200 m3/h and heat exchanger efficiency up to 88%. They provide supply of fresh filtered air and extract impure air from the premises. They are compatible with round air ducts with nominal diameters of 125, 150, 160, 200, 250, 315 mm.

Available modifications and technical parameters of VENTS VUT H

ModelVUT 350 HVUT 500 HVUT 530 HVUT 600 HVUT 1000 HVUT 2000 H
Voltage [V / Hz]1~ 220-240 / 50-601~ 220-240 / 50-601~ 220-240 / 50-601~ 220-240 / 50-601~ 220-240 / 50-601~ 220-240 / 50-60
Maximum fan power [W]2pcs. х 1302pcs. х 1502pcs. х 1502pcs. х 1952pcs. х 4102pcs. х 650
Fan current [А]2pcs. х 0,62pcs. х 0,662pcs. х 0,662pcs. х 0,862pcs. х 1,82pcs. х 2,84
Total unit power [W]2603003003908201300
Total unit current [А]1,21,321,321,723,65,68
Air capacity [m3/h]35050053060012002200
RPM115011001100135018501150
Sound pressure level at 3 m [dBA]24-4528-4728-4732-486065
Transported air temperature [°C]-25 up to +55-25 up to +50-25 up to +50-25 up to +55-25 up to +40-25 up to +40
Casing materialaluzincaluzincaluzincaluzincaluzincaluzinc
Insulation25 mm mineral wool25 mm mineral wool25 mm mineral wool25 mm mineral wool50 mm mineral wool50 mm mineral wool
Filter: extractG4G4G4G4G4G4
Filter: supplyF7 (EU7)F7 (EU7)F7 (EU7)F7 (EU7)G4 (F7*)G4 (F7*)
Connected air duct diameter [mm]Ø125Ø150Ø160Ø200Ø250Ø315
Weight [kg]454949548596
Heat recovery efficiencyup to 78 %up to 88 %up to 88 %up to 85 %up to 88 %up to 87 %
Heat exchanger typecross-flow typecross-flow typecross-flow typecross-flow typecross-flow typecross-flow type
Heat exchanger materialaluminiumaluminiumaluminiumaluminiumaluminiumaluminium

*option

Detailed information on the VENTS VUT H at our website.

Description

Air handling unit VUT H is a complete ventilation units designed for air filtration and supply to the premises and exhaust air removal. During the operation process the extract air heat is transferred to the supply air through the plate heat exchanger. All the models are designed for connection with Ø 125, 150, 160, 200, 250, 315 mm round ducts.

Casing

The casing is made of aluminium profile, double skinned with 20 mm mineral wool heat-and sound-insulating layer.

Filter

Two incorporated G4 panel filters for extract air ventilation and F7 filters for supply air ventilation are supplied with the unit.

Fans

The unit is equipped with supply and exhaust centrifugal double-inlet fans with forward curved blades and built-in thermal overheating protection with automatic restart. The electric motors and impellers are dynamically balanced in two planes. The ball-bearings used with motors are designed for at least 40 000 hours operation and are maintenance-free.

Heat exchanger

The cross-flow air-to-air heat exchanger block is manufactured from aluminum plates. Whenever heat recovery is not required the heat exchanger block can be easily replaced by a "summer" block. The unit is also equipped with the drain pan for condensate water drainage as well as built-in freezing protection system. Its operating principle is based on switching the supply fan off as the temperature sensor requires. Warm extract air heats the heat exchanger. Then the supply fan switches on and the unit continues operating under rated conditions.

Control

The motor speed is controlled by means of 4-step control switch by means of selecting the minimum, average or maximum speed or the unit shutdown.

Mounting

Air handling unit is mounted on the floor and suspended to the ceiling by means of a seat angle with anti-vibration mounts or attached to a wall with brackets. The unit can be mounted either in service spaces or in main premises above the suspended ceiling, in the pocket or can be placed directly in the room. Mounting in any position shall provide correct condensate drainage. Access for the fan maintenance and filter cleaning shall be provided from outside of the side panels.

VENTS VUT H unit air exchange example in the flat

Products from the category - Floor-mounted air handling units with heat recovery

 
 
 

On-site search

Search

Catalogue of products

Contacts

vents
(main office)

01030, Ukraine, Kyiv, Київ, М. Коцюбинського, 1
  • +38 (044) 406-36-XX

Sites

 
 

 
 

 
 
 
Write a message
Select message form:
 
 
 
Ідентифікатор сторінки
Ідентифікатор сторінки:
1234

Search
 
 

Close
 
 
Order a call
person
phone
email
record_voice_over
create